What is the duration of air supply in an SCBA unit?

Categories: Product Information, Respiratory Protection, Technical Support

Our standard cylinder is rated at 300 bar. A 6.8L cylinder filled to this pressure can theoretically provide approximately 50 minutes of air supply. However, actual usage time can vary significantly based on factors like breathing rate, physical exertion, and other conditions. We strongly recommend allowing a 10-minute safety margin, resulting in an effective duration of around 40 minutes.

To calculate the theoretical air duration, you can use the following formula:

  • Duration = (Pressure x Volume) / 40
    • For example, with a 6.8L cylinder at 300 bar:
    • Duration = (300 bar x 6.8 L) / 40 = 51 minutes

Again, this is a theoretical calculation, and actual usage time will be shorter.

Important: Always prioritize safety and consider the potential for reduced air supply under demanding conditions.

This entry was posted in . Bookmark the permalink.

Important Notice: Our Shop is Almost Ready! Hi there! 👋 We’re excited to welcome you soon, but our e-commerce features are currently undergoing final testing to ensure a seamless experience for our launch on 01 May 2025. Please note: ✅ All prices shown are dummy values (RM0 or otherwise) for testing purposes. ✅ Checkout and orders are not functional at this time. Thank you for your patience and understanding! We’re working hard to create a fantastic shopping experience for you. Stay tuned—see you on launch day! 🎉 Dismiss