Product Details
The SAFETYWARE EV Pro Class 00 Electrical Insulating Gloves are designed to protect workers from electrical shocks while handling live electrical equipment. These gloves are crafted from natural rubber and feature a smooth palm pattern, offering both comfort and durability. The bright orange color enhances visibility, ensuring added safety in low-light conditions, while the soft design minimizes hand fatigue during extended tasks.
Key Features and Benefits
- Electrical Shock Protection: Offers reliable protection against electrical shocks for safe handling of live equipment.
- Enhanced Visibility: Bright orange color improves visibility in dim environments, enhancing worker safety.
- Durable Construction: Made from sturdy natural rubber, these gloves ensure long-lasting use and reduce replacement frequency.
- Comfortable Fit: Available in multiple sizes (8-11) to reduce hand fatigue and ensure a snug fit for extended use.
- Compliance with Safety Standards: Certified to EN 60903:2003 and EN ISO 21420:2020, and REACH Compliant for superior safety and quality assurance.
Recommended For
Class 00 Electrical Insulating Gloves are ideal for electricians, maintenance workers, and others working with live electrical equipment who require reliable protection from electrical shocks. They are particularly suitable for environments where high visibility is critical for safety.
Industries
- Electrical Maintenance
- Power Generation
- Construction
- Utility Services
Specifications
- Type: Class 00 – 500V
- Material: Natural Rubber
- Palm Pattern: Smooth
- Cuff Style: Beaded
- Color: Orange
- Size: 8-11
- Packing: 1 pair/box, 10 pairs/carton
Packaging
Each pair is individually packed in a box, with 10 pairs per carton for convenient bulk storage and distribution.
Approvals
- EN 60903:2003 – Complies with the standards for electrical insulating gloves.
- EN ISO 21420:2020 – Ensures general glove safety and performance.
- REACH Compliant – Certified for safety in chemical use and handling.
SAFETYWARE EVPro™ VLT-C00 Class 00 Electrical Rubber Insulating Gloves Selection Notes
The SAFETYWARE EVPro™ VLT-C00 Class 00 Electrical Rubber Insulating Gloves is part of Safetyware’s hand and arm protection range for teams that want dependable PPE without making glove selection complicated. It is best reviewed against the actual task, the surfaces handled, exposure duration and the level of dexterity workers need during the shift.
Where It Fits
| Selection area | Practical guidance |
|---|---|
| Product family | Chemical Resistant Gloves |
| Typical application | Chemical handling in factories, workshops, construction, laboratories, logistics or maintenance areas. |
| Procurement note | Check the SDS, material compatibility, cuff length and expected contact time before use. |
Standards and Procurement Notes
For chemical exposure, compare the SDS against EN ISO 374 claims, permeation data and breakthrough guidance. For Malaysia and Singapore users, the most reliable approach is to document the hazard, shortlist suitable glove materials or ratings, then run a wearer trial before standardising bulk supply.
Common Questions
Can this replace every glove on site?
No. Hand protection should be matched to each task. Cut, chemical, electrical, heat, cold and cleanroom hazards can require very different glove materials and markings.
Can I request datasheets or samples?
Yes. Contact Safetyware to compare sizing, documentation, sample options and suitable alternatives for your workplace.
Browse related Chemical Resistant Gloves options if you are comparing similar gloves or sleeves for a wider PPE programme.
SAFETYWARE EVPro™ VLT-C00 Class 00 Electrical Rubber Insulating Gloves Selection Notes
The SAFETYWARE EVPro™ VLT-C00 Class 00 Electrical Rubber Insulating Gloves is part of Safetyware’s electrical protection range for electricians, utilities, industrial maintenance teams, substations and facilities that need controlled protection against shock, arc flash, short-circuit or emergency rescue hazards. Review it against the actual task, voltage exposure, isolation status and site procedure before issue.
Where It Fits
| Selection area | Practical guidance |
|---|---|
| Product family | Arc flash PPE |
| Typical application | Electrical maintenance, switching, testing, isolation, substation work, panel service or emergency readiness. |
| Procurement note | Match arc rating, coverage, visor or hood, gloves and site arc-flash assessment. |
Standards and Safe Work Notes
Electrical protection should support a planned safe-work sequence: isolate where practical, lock out and tag out, verify absence of voltage, control stored energy, then use rated PPE and tools for the remaining risk. Local buyers should confirm datasheets, applicable EN/IEC/ASTM markings and DOSH/SIRIM KPD documentation where required.
Common Questions
Can this be used for live electrical work?
Only if the product rating, condition, procedure and user competency match the task. Electrical work should be de-energised and isolated whenever practical.
Can I request datasheets or matching accessories?
Yes. Contact Safetyware to compare ratings, sizes, compatible accessories or documentation for your site.
Browse related Electrical Body Protection products if you are building a complete electrical safety set.